For all fault finding, first check that the supply voltage is between 10 - 32 Vdc.
3YMPTON #HECK 2EMEDY
No picture on display
screen
Check that the unit is
turned on
Press [PWR] key on keypad
Check fuse in EQ32 MKII
power cable.
F See warning below.
Replace fuse. Use only
type 2 AmpF
Picture appears on the dis-
play screen, but image is
too dark or too bright
Adjust the image as desired
by pressing the [PWR] key,
adjust light/contrast, and
press the [MENU] key
Echo picture appears nor-
mal, but no targets are
shown or only random
noise is seen
Check that the transducer
connector are securely
mated with the console
Correctly mate the
connector to the console
Check that the receiver
gain is set high enough
Increase the receiver gain.
See Chapter 2 -
Echosounder menu,
Presentation setup section
Check that the range is
correct for the water depth
Adjust the range. See
Chapter 2 - Echosounder
menu, Presentation setup
section
Check that the Demo mode
is not active
Go to Echosounder setup
in Echosounder menu and
set Demo mode to OFF
No normal picture Turn unit off and on again.
No response to key opera-
tion
Disconnect power and
connect again
No normal picture or key
operation
Perform master reset, refer
to section 4.3
You can not make the sys-
tem switch between 50 kHz
and 200 kHz
Check that the Demo mode
is not active
Go to Echosounder setup
in Echosounder menu and
set Demo mode to OFF
Warning! Do not operate the unit without a fuse. When replacing the fuse, make sure to
use the same type of fuse again (2 AmpF), as any other type may cause severe damage
to the unit.
4ROUBLESHOOTINGPROCEDURE