Simrad NSS Guía de instalación Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
|
17
Wiring the NSS | NSS Installation Manual
Wiring the NSS
Wiring guidelines
Don’t do this Do this
Don’t make sharp bends in the cables Do make drip and service loops
Don’t run cables in a way that allows water
to  ow down into the connectors
Do tie-wrap all cables to keep them secure
Don’t route the data cables in areas adjacent
to radar, transmitter, or large current carrying
cables
If cables are shortened, lengthened, or
re-terminated, do insulate and protect all
wiring connections
Do leave room at the back to install and
remove cables
!
Warning: Before starting the installation, be sure to turn electrical power o . If power is
left on or turned on during the installation,  re, electrical shock, or other serious injury may
occur. Be sure that the voltage of the power supply is compatible with the NSS display
!
Warning: The NSS has a voltage rating of 12 V DC or 24 V DC. (9 V DC - 32 V DC max
range). SimNet is 12 V DC only
!
Warning: The red wire should always be connected to (+) DC V using a fuse or thermal
breaker (10 Amp)