Simrad SH90 - REV B Especificaciones

Busca en linea o descarga Especificaciones para No Simrad SH90 - REV B. Simrad SH90 - REV B Specifications [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - M A N U A L

M A N U A LSimrad EQ44/54Echosounder183-3403-102 English 05082.20

Pagina 2

Chapter 1-4 EQ44/54 Introduction and safety summary  To call up an echo display will require that the connected transducer type has been selected in

Pagina 3

WARRANTY CARDTO BE RETAINED BY THE OWNER_____________________________________________ ___________________________________________OWNER VESSEL_________

Pagina 4

tear outWARRANTY CARDTo be mailed to the NATIONAL DISTRIBUTOR (see overleaf)together with the installation report WITHIN 14 DAYSfrom the date of insta

Pagina 5

NATIONAL SIMRAD DISTRIBUTOR:__________________________________________________________________________________________________________________________

Pagina 6

EQ44/54 Introduction and safety summary Chapter 1-51.3.2 Echosounder featuresA-scope - Press [ENT], [2] to toggle A-scope on/off. Echoes are displaye

Pagina 7

Chapter 1-6 EQ44/54 Introduction and safety summary

Pagina 8 - 1.2 Safety summary

B-LCK display ZOOM display STND display SHIFT displayEQ44/54 Fundamentals & initial start-up Chapter 2-12.1 Fundamentals of the display and page

Pagina 9 - 1.3 How to get started

Chapter 2-2 EQ44/54 Fundamentals & initial start-upLong press on the [PAGE] key will start a rotation of the four pages in intervals of 5 seconds

Pagina 10

EQ44/54 Fundamentals & initial start-up Chapter 2-3Highlight a function e.g. Depth & temperature diagram in the MISC menu.WIN Press [WIN] se

Pagina 11

Chapter 2-4 EQ44/54 Fundamentals & initial start-upB-LCK Shortcut to bottom lock displays. Long press will toggle between bottom lock display in

Pagina 12

EQ44/54 Fundamentals & initial start-up Chapter 2-52.3 Menu barMENU Toggles the menu bar on /offTo fit the complete menu bar across the screen,

Pagina 13

Chapter 2-6 EQ44/54 Fundamentals & initial start-up2.4 Menu layout1STND2B-LCK3ZOOM1 50kHz1 50kHz1 50kHz2 200kHz2 200kHz2 200kHz3 Dual frequency3

Pagina 14

Automatic input source setupInterface has not been set up! To start automatic inputsource setup, make sure thatall connected products areturned ON, an

Pagina 16

Chapter 2-8 EQ44/54 Fundamentals & initial start-upPWR Press [PWR] again to adjust the lighting in the screen and select day or night display et

Pagina 17 - 2.3 Menu bar

EQ44/54 Echosounder operation Chapter 3-13. Echosounder operationThe echosounder function of the EQXX determines the distance between its transducer

Pagina 18 - 2.4 Menu layout

Chapter 3-2 EQ44/54 Echosounder operation3.1 Parts of an echosounderAn echosounder is composed of a display screen, processor, and transmitter/ recei

Pagina 19 - 2.5 Initial start-up

EQ44/54 Echosounder operation Chapter 3-33.2 How the echosounder worksWhen the EQXX is turned on, a transmitter begins to send electrical pulses to t

Pagina 20 - 2.7 Turn power off

Chapter 3-4 EQ44/54 Echosounder operation3.3 Transducer beam widthThe transducer mounted to the hull of your vessel serves as both a ‘speaker’ when t

Pagina 21 - 3. Echosounder operation

EQ44/54 Echosounder operation Chapter 3-53.4 Effects of the vessel’s speedThe presentation of fish on the EQXX depends directly on the vessel’s speed

Pagina 22 - 3.1 Parts of an echosounder

Chapter 3-6 EQ44/54 Echosounder operation

Pagina 23 - 3.2 How the echosounder works

EQ44/54 STND menu Chapter 4-14.1 STND menu1STND1 50kHz (38kHz)2 200kHz3 Dual frequency4 Custom screen 15 Custom screen 2Low and high frequency echoso

Pagina 24 - 3.3 Transducer beam width

Chapter 4-2 EQ44/54 STND menuFrom any display:STND Long press on the [STND] key will toggle between: 38/50kHz or 200kHz full scr

Pagina 25

EQ44/54 STND menu Chapter 4-31-9 Select range in 9 steps+/- Adjust range with the + and - keys0 Activate Auto range Press cursor left/right to a

Pagina 26

EQ44/54 Echosounder Table of contentsChapter 1 Introduction and safety summary1.1 Introduction and system familiarization ...

Pagina 27 - 4.1 STND menu

Chapter 4-4 EQ44/54 STND menu4.5 Echo quick menuA number of echo features can easily be accessed from the Echo quick menu. From active echo display:E

Pagina 28 - 4.3 Standard echo display

EQ44/54 STND menu Chapter 4-54.7 Presentation setupThe general Echosounder setup e.g. Selecting transducer, Alarm set-tings, Demo mode etc. is placed

Pagina 29 - 4.4 Variable range marker

Chapter 4-6 EQ44/54 STND menuRange – refers to the distance shown from the top to the bottom of the display screen. Selecting Auto range will cause t

Pagina 30 - 4.5 Echo quick menu

EQ44/54 STND menu Chapter 4-7Ping to ping filter – can be set to either on or off. With the filter “off”, then each received echo will be reflected o

Pagina 31 - Setup 200kHz:

Chapter 4-8 EQ44/54 STND menuScroll speed – is the ping rate and movement of the presentation of echoes on the screen, moving from right to left. It

Pagina 32

EQ44/54 B-LCK menu Chapter 5-15.1 B-LCK menu2B-LCK1 50kHz (38kHz)2 200kHz3 Dual frequency4 Custom screen 15 Custom screen 2Low and high frequency ech

Pagina 33

Chapter 5-2 EQ44/54 B-LCK menuThe advanced bottom lock and expansion feature ensures a reli-able depth readout and provides a compressed standard dis

Pagina 34

EQ44/54 ZOOM menu Chapter 6-16.1 ZOOM menu3ZOOM1 50kHz (38kHz)2 200kHz3 Dual frequency4 Custom screen 15 Custom screen 2Low and high frequency echoso

Pagina 35 - 5.1 B-LCK menu

Chapter 6-2 EQ44/54 ZOOM menuThis feature will provide an expanded view of the area near the *VRM line which will give a better separation of echoes.

Pagina 36

EQ44/54 SHIFT menu Chapter 7-17.1 SHIFT menu4SHIFT1 50kHz (38kHz)2 200kHz3 Dual frequency4 Custom screen 15 Custom screen 2Low and high frequency ech

Pagina 37 - 6.1 ZOOM menu

Table of contents EQ44/54 EchosounderChapter 7 SHIFT menu7.1 SHIFT menu...

Pagina 38

Chapter 7-2 EQ44/54 SHIFT menuThis feature can be applied when operating in deep waters. The expansion window can automatically follow a changing bot

Pagina 39 - 7.1 SHIFT menu

EQ44/54 PILOT menu Chapter 8-18. PILOT menu5PILOT1 Highway2 Position8.1 Highway displayTo present any information in the EQXX highway display will re

Pagina 40

 Chapter 8-2 EQ44/54 PILOT menuENT Return to Highway displayHighway display (with active navigation mode)Nautical miles indication (0.10nm and 0

Pagina 41 - Navigation setup:

External POS15-08-2004EQ44/54 PILOT menu Chapter 8-38.2 Position display To present a position will require that the echosounder is con-nected to a

Pagina 42

Chapter 8-4 EQ44/54 PILOT menuCLR Reset log0-9 Key in new values, or...+/- Toggle between available valuesENT Confirm editing and return to the P

Pagina 43 - Pos display setup:

EQ44/54 Miscellaneous menu Chapter 9-19. Miscellaneous menu6MISC1 Decca lanes2 Loran C3 Depth & temperature diagram9.1 Decca lanesTo change the p

Pagina 44

Chapter 9-2 EQ44/54 Miscellaneous menuList of decca chains:00 S Baltic 0A 24 Skagerak 10B01 Vestlandet 0E 25 N Persian 5C02 SW B

Pagina 45 - 9. Miscellaneous menu

EQ44/54 Miscellaneous menu Chapter 9-39.2 Loran CTo change the position readouts to Loran C mode, see section 10.2 under Pilot/Position setup, where

Pagina 46

Chapter 9-4 EQ44/54 Miscellaneous menuList of Loran C chains:Central PacificGulf of AlaskaSoutheast U.S.Great LakesNortheast U.S.Canadian West CoastC

Pagina 47 - 9.2 Loran C

EQ44/54 Miscellaneous menu Chapter 9-59.3 Depth & temperature diagramMENU Call up the menu bar, and...6,3 activate Depth & temperature diag

Pagina 48

EQ44/54 Echosounder Table of contents11.6.2 Determining the position for the transducer ... 11-1811.7 Preventive maintenan

Pagina 49 - Setup for Depth:

Chapter 9-6 EQ44/54 Miscellaneous menu0-9 Key in new figures, or...+/- change settingsENT Confirm changesScale for depth - there are six depth sca

Pagina 50

EQ44/54 SETUP menu Chapter 10-110. Setup menu7SETUPSTND Echosounder setup - see section 10.11 Pilot/Position setup - see section 10.22 Speed alarm, u

Pagina 51 - 10. Setup menu

Chapter 10-2 EQ44/54 SETUP menuEchosounder setup:Select transducers: TYPE PORT Transducer 1:

Pagina 52 - Echosounder setup:

EQ44/54 SETUP menu Chapter 10-3Depth DS fish - define a specific area below the water surface of minimum and maximum depth for the fish alarm.Depth D

Pagina 53

Chapter 10-4 EQ44/54 SETUP menu10.2 Pilot / Position setupMENU Call up the menu bar, and...7,1 load Pilot/Position setup displayPilot/Pos setup:Di

Pagina 54 - Pilot/Pos setup:

EQ44/54 SETUP menu Chapter 10-510.3 Speed alarm, units & languageMENU Call up the menu bar, and...7,2 load Speed alarm, units & language di

Pagina 55 - Setup for units:

Chapter 10-6 EQ44/54 SETUP menuDistance in - can be calculated in nautical miles (nm), kilometers (km) or statute miles (mi).Speed in - can be shown

Pagina 56

EQ44/54 SETUP menu Chapter 10-710.4 Interface setupEQ44/54 has two NMEA in/out ports:1. NMEA1 is a standard NMEA0183 port.2. NMEA2 is used for connec

Pagina 57 - 10.4 Interface setup

◄ GAIN- Position Navigation GAIN+►+ 1: Simrad EQ44 ,Sn:100003+ 2: Simrad CA34-3 ,Sn:0070B0+ 3: Airmar EQS ,Sn:0

Pagina 58

◄ GAIN- Nodes Position GAIN+►Input: Group selection: SIMRAD Source (one available): Simrad CA34-3 ,Sn:5C514DMENU

Pagina 59

Table of contents EQ44/54 Echosounder

Pagina 60 - Water speed input:

◄ GAIN- Navigation Compass Wind Al GAIN+►Water depth input: INTERNAL ONLY Group selection: SIMRAD Source (multi

Pagina 61

◄ GAIN- Navigation Water GAIN+ ►Input: Group selection: SIMRAD Source (none available): NONEMEN

Pagina 62 - Identification

◄ GAIN- 83 output GAIN+ ►Unit description: ECHO SOUNDERDevice instance 000System instance 000MEN

Pagina 63

EQ44/54 SETUP menu Chapter 10-13MENU exit function without making any changes10.4.1 Description of sentencesDescription of NMEA0183 version 3.0 outp

Pagina 64 - 10.5 Palette setup

Chapter 10-14 EQ44/54 SETUP menu10.5 Palette setup  Quick change of preset color palettes via the [PWR] key.MENU Call up the menu bar, and...7,4

Pagina 65 - 10.6 Factory settings

EQ44/54 SETUP menu Chapter 10-15Alphanumeric names:First select the key with the desired letter, then you can either repeat the keystrokes, which wil

Pagina 66

Chapter 10-16 EQ44/54 SETUP menuMENU If not absolutely sure, press [MENU] to exit function without having made any changes  Activating ‘Return to

Pagina 67 - 10.7 QuickGuide

EQ44/54 SETUP menu Chapter 10-1710.7 QuickGuideA description of the key functions and general guidance is available in a QuickGuide, which can be acc

Pagina 68

Chapter 10-18 EQ44/54 SETUP menu

Pagina 69 - 11. Installation and service

EQ44/54 Installation and service Chapter 11-111. Installation and service11.1 I n s t a llat ion notesFor a number of reasons, all user-related de

Pagina 70 - Other important settings:

EQ44/54 Introduction and safety summary Chapter 1-11.1 Introduction and system familiarizationCongratulations on your purchase of SIMRAD EQ44/54 Echo

Pagina 71 - Console mounting

Chapter 11-2 EQ44/54 Installation and serviceOther important settings:

Pagina 72

52 (2.1”)343 mm (13.5”)365 mm (14.4”)220 mm (8.8”)245 mm (9.6”)110 mm (4.3”)75 mm (3.0”)EQ44/54 Installation and service Chapter 11-311. 2 I n s t

Pagina 73

347 mm (13.7”)337 mm (13.3”)353 mm (13.9”)365 mm (14.4”)192 mm (7.6”)202 mm (7.9”)208 mm (8.2”)220 mm (8.7”)Chapter 11-4 EQ44/54 Installation and se

Pagina 74

52 (2.1”)343 mm (13.5”)460 mm (18.1”)330 mm (13”)339.2 mm (13.4”)195 mm (7.7”)EQ44/54 Installation and service Chapter 11-511. 3 I n s t a llat i o

Pagina 75

427.9 mm (16.8”)437.9 mm (17.2”)448 mm (17.6”)460 mm (18.1”)297.9 mm (11.7”)307.9 mm (12.1”)318 mm (12.5”)330 mm (13”)Chapter 11-6 EQ44/54 Installat

Pagina 76 - 11.5 Electrical connections

EQ44/54 Installation and service Chapter 11-711.4 Location for display unitDetermine which place is the most suitable and convenient for navigation

Pagina 77

/ AT44Chapter 11-8 EQ44/54 Installation and service11.5 Electrical connections

Pagina 78

EQ44/54 Installation and service Chapter 11-9

Pagina 79

Chapter 11-10 EQ44/54 Installation and service11.5.1 Power supply connections The internal voltage regulator will allow the EQ44/54 to operate norma

Pagina 80 - AT44 Active Tee

EQ44/54 Installation and service Chapter 11-11Transducer connections: Internal connections Transceiver Transceiver 1

Pagina 81

Chapter 1-2 EQ44/54 Introduction and safety summary1.2 Safety summaryPrecaution: Do not open the equipment, only qualified persons should work inside

Pagina 82

xx44/54NMEA2AT44 Active TeeSimNetChapter 11-12 EQ44/54 Installation and service11.5.4 Interface connectionThe 44 and 54 series feature three possibi

Pagina 83

EQ44/54 Installation and service Chapter 11-13SimNet power and terminationThe following simple rules should be observed when installing SimNet:• Sim

Pagina 84

Chapter 11-14 EQ44/54 Installation and service11.6 Basic transducer and cable information For optimum performance of the Echosounder, the Simrad com

Pagina 85

EQ44/54 Installation and service Chapter 11-1511. 6.1 Tra ns du cers (o pt io n)Simrad Combi-transducers C50/200 or C38/200Combi C50/200 or C38/200

Pagina 86

Chapter 11-16 EQ44/54 Installation and service Airmar P319 Thru-hull mountFrequency: 50/200 kHzBeamwidth: 45° / 15°Cable leng

Pagina 87

EQ44/54 Installation and service Chapter 11-17 Airmar SS505 Ref.no. 179-0401-011 Optional fairing Thru-hul

Pagina 88 - 11.8 Repair and service

Chapter 11-18 EQ44/54 Installation and service Airmar B744VThru-hull triducerFrequency: 50/200 kHzBeamwidth: 45° / 15°Cable length: 10m (32’)S

Pagina 89 - 11.9 Trouble s hoo t i ng

EQ44/54 Installation and service Chapter 11-19Due to the varying design of ship’s hulls and different operating speeds, there can be great variation

Pagina 90 - 11.10 Speci f icatio n s

Chapter 11-20 EQ44/54 Installation and service11.7 Pr eventive maint e n a n ceSurface cleaning – to keep the EQ44/54 cabinet and display screen cl

Pagina 91

EQ44/54 Installation and service Chapter 11-2111.9 Trouble s hoo t i ngFor all fault finding, first check that the supply voltage is between 10-32 V

Pagina 92

Automatic input source setupInterface has not been set up! To start automatic inputsource setup, make sure thatall connected products areturned ON, an

Pagina 93

Chapter 11-22 EQ44/54 Installation and service11.10 Speci f icatio n sGeneral dataPower supply: 12 and 24 V DC (10-32 V DC max) 25 wattsPower cable

Pagina 94

EQ44/54 Installation and service Chapter 11-23Pulse length: Short, medium, long and autoTransmissionrate: Max. 25 pings per secondAlarms: Fish,

Pagina 95

Chapter 11-24 EQ44/54 Installation and serviceSimNet cable 10 m (33’), (24005852)SimNet cable Tee Joiner (24005860)SimNet cable gland (24005878)SimN

Pagina 96 - ZOOM menu 6-1

EQ44/54 Glossary of terms Appendix A-1Alarms – can be set to sound a “beep” if the echosounder detects a target above (shallower than) a minimum alar

Pagina 97 - EQ44/54 Echosounder Index

Appendix A-2 EQ44/54 Glossary of termsMENU – the selection of main menus will be shown in the upper part of the screen. Leaf through the menus by mea

Pagina 98 - EU Declaration of Conformity

EQ44/54 Echosounder IndexAgents end of manualAlarms,- depth 10-2,A-1- fish 10-2- speed 10-5- XTE 8-1,A-2Alphanumeric names 10-15B-LCK

Pagina 99 - Warranty

Index EQ44/54 EchosounderInstallation - continued,- EQ54 11-5- determining the position for the transducer 11-18- location for display unit 11-

Pagina 100 - WARRANTY CARD

EQ44/54 Echosounder Index

Pagina 101

EU Declaration of ConformityI, the undersigned, hereby declare that the following equipment complies with therelevant essential requirements in the EM

Pagina 102

WarrantySIMRAD warrants that every product shall be free of defects in material and workmanship as specified below:CATEGORY “A”: •Autopilots •Radars

Comentarios a estos manuales

Sin comentarios