Simrad EQ 55 Información técnica Pagina 137

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 154
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 136
EQ-55 Operators Manual 950-7001001/Iss 1.
2
Introduction and System Familiarization Page 7.
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
7.7 EQ 55 CPU CIRCUIT BOARD JUMPER CONFIGURATIONS
Jumper Function Configuration
J1 RESET EQ 55 Open (closing jumper will force
/RESET)
JP2 Speed Input (Open Collector) Jumper across pins 1 to 2
Speed Input (Switch Closure) Jumper across pins 3 to 4
JP3 Interrupt 2 x 2 jumper across pins 1 to 2, and
pins 3 to 4
EQ 55 Transceiver Circuit Board Jumper Configurations
Jumper Function Configuration Notes
LK1
LK2
LK3
High Frequency channel transmit
output impedance select
Jump LK1 = 60W
Jump LK2 = 100W
Jump LK3 = 200W
Select impedance to match
transducer
LK4
LK5
LK6
Low Frequency channel transmit
output impedance select
Jump LK4 = 60W
Jump LK5 = 100W
Jump LK6 = 200W
Select impedance to match
transducer
LK11 Operate/Calibrate ADC input Jumper in position 1 of
LK11 to operate.
(Position 2 will ground
input of ADC. Do not use
in this configuration.)
Vista de pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 153 154

Comentarios a estos manuales

Sin comentarios