Simrad PI Sensor adapter installation
10
857-164919 / Rev.B
STEP 5: Weld the sensor adapters to the doors
Tack weld sensor adapters in position using the reference line
created in step 3 as a guide. Check that both angle and
orientation are in agreement with the drawings.
Permanently weld the sensor adapters to the doors using 7 to 10
cm long beads, it is not necessary to use a continuous weld.