Technicalspecications
Powerrequirements
ThissectionprovidesthetechnicalspecicationsandrequirementsrelatedtotheAC
mainssupply.
DisplayUnit
Notapplicable.Refertothedocumentationprovidedbythemanufacturer.
APC12ProcessorUnit
Voltagerequirement:115/230V ac/47–63Hz/singlephase,selectable(nominal)
Deviation:15%
Transient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:Approximately150V A
Recommendedcircuitbreaker:10A,slow
TransceiverUnit
Voltagerequirement:230Vac/50–60Hz/singlephase(nominal)
Deviation:15%
Transient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:
TRCComputers:6x400W=2.400W
Ethernetswitch:100W
Fanunit:100W
Recommendedcircuitbreaker:2x10A,slow
PowerSupplyUnit
Voltagerequirement:230Vac/50–60Hz/singlephase(nominal)
Deviation:15%
Transient:20%ofnominalvoltage,recoverytime3s
Powerconsumption:Approximately800W(eachcabinet)
Recommendedcircuitbreaker:10A,slow(eachcabinet)
331549/B